GET THE APP

..

Nuclear Medicine & Radiation Therapy

ISSN: 2155-9619

Open Access

Volume 1, Issue 1 (2010)

Research Article Pages: 1 - 8

Six Degree-of-Freedom Image Guidance for Frameless Intracranial Stereotactic RadioSurgery with kilo-voltage Cone- Beam CT

Zheng Chang, Zhiheng Wang, Jinli Ma, Q. Jackie Wu, Scott Senick, Ryan McMahon, John P. Kirkpatrick and Fang-Fang Yin

DOI: 10.4172/2155-9619.1000101

Abstract Purpose: To investigate localization accuracy for frameless intracranial stereotactic-radiosurgery using 2D orthogonal planar imaging and 3D cone-beam CT (CBCT) in 6-degree-of-freedom (6-DOF).

Methods and Materials: In a phantom study, a target ball phantom was used to perform a Winston-Lutz test and to verify coincidence of imaging isocenter and radiation isocenter. A head phantom was placed with pre-defined positions and imaged with CBCT to test imaging accuracy. In a patient study, one hundred patients were included. Patients were initially positioned with a thermoplastic frameless mask system and then aligned with orthogonal planar imaging and CBCT. The setup discrepancies were quantitatively analyzed.

Results: Phantom experiments showed discrepancies in root-mean-square were 1.6mm translationally and 0.5° rotationally between CBCT 6-DOF image guidance and the known displacements after deviations from the radiation isocenter are considered. In the patient study, setup displacements between orthogonal planar imaging and CBCT 6-DOF image guidance were 3.2mm translationally and 0.9° rotationally. The positioning of twelve patients was corrected in 6-DOF using CBCT and a robotic couch to reduce translational and rotational discrepancies of 1.4mm and 1.3°, as compared with standard CBCT translational correction. Conclusion: CBCT 6-DOF image guidance offers an explicit view to verify patient positioning in translations and rotations.

Research Article Pages: 1 - 6

Evaluation of Early Response to Neoadjuvant Chemotherapy in Breast Cancer Patients by 18F-FDG and 99mTc-HL91 Imaging

Zhan Song, Zhe Wang, Li-Wen Li, Jiang-Hao Chen and Jing Wang

DOI: 10.4172/2155-9619.1000102

By monitor breast cancer mass with 18F-fluorodeoxyglucose (FDG) and 99mTc-HL91 positron emission tomography (PET) imaging, this study compares the efficacy of the two imaging methods in evaluation of the early response to neoadjuvant chemotherapy in stage II and III breast cancer patients. Images of region of interest were acquired with a hybrid PET/computed tomography scanner in forty patients after administration of 18F-FDG (4.44 MBq/kg) or 99mTc-HL91 (12.3 MBq/kg) at baseline and after the third course of chemotherapy. And the values of tumor to non-tumor activity ratio (T/N) were compared between the two imaging methods and with the pathologic response. Surgery was performed after three courses of chemotherapy and pathological analysis revealed gross residual disease in 11 patients and minimal residual disease in 29 patients. When 20% reduction in T/N was set as the threshold for differentiation between responders and nonresponders by 18F-FDG imaging, 27 of 29 responders and 10 of 11 nonresponders were identified after three courses of chemotherapy. A linear correlation was observed between the T/N of 99mTc-HL91 and the T/N of 18F-FDG (rs = 0.778, p<0.001), but almost lost after chemotherapy (rs = 0.518, p<0.001). In conclusion, we suggest that 18F-FDG imaging, but not 99mTc–HL91 imaging with hybrid PET/CT provides a costeffective method, which could be well accepted for the low-income population in developing countries, to monitor early tumor response after three cycles of neoadjuvant chemotherapy in stage II and III breast cancer by using the reduction of N/T ratio as predictor.

Google Scholar citation report
Citations: 706

Nuclear Medicine & Radiation Therapy received 706 citations as per Google Scholar report

Nuclear Medicine & Radiation Therapy peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward