Point of care diagnosis of bacterial vaginosis by detection of biogenic amines using ion mobility spectrometry (IMS) in a routine ambulatory care gynecology clinic
..

Metabolomics:Open Access

ISSN: 2153-0769

Open Access

Point of care diagnosis of bacterial vaginosis by detection of biogenic amines using ion mobility spectrometry (IMS) in a routine ambulatory care gynecology clinic


5th International Conference and Exhibition on Metabolomics

May 16-18, 2016 Osaka, Japan

Simon D Lytton

SeraDiaLogistics Munich, Germany

Posters & Accepted Abstracts: Metabolomics

Abstract :

Purpose: A new CE-marked portable desktop ion mobility spectrometer (VGTest) was used for detection of malodorous biogenic amines indicative of bacterial vaginosis (BV). This study aimed to assess the performance of this testing method for the first time in a routine ambulatory care clinic and to determine the relative levels of biogenic amines in vaginal fluid of BV. Methods: Vaginal and cervical swabs (n=57) were surveyed for infections. Cases of BV (n=18) confirmed positive according to ��Amsel�� criteria and normal controls (n=39) showing no infection under clinical examination and testing negative in wet mount microscopy were included in the IMS analysis. Results: The trimethylamine (TMA) content in vaginal fluid of the BV-positive cases, AUCTMA/AUCTotal [mean 0.215 (range 0.15� 0.35)] was significantly higher than normal controls [mean 0.06 (range 0.048�0.07)] p\0.0001. The putrescine (1,4-diaminobutane, PUT) and cadaverine (1,5-diaminopentane, CAD) of BV-positive cases were above controls at borderline significance. The AUCTMA/AUCTotal ratios correlated neither with AUCPUT/ AUCTotal nor AUCCAD/AUCTotal among BV-positive patients. In contrast, among normal controls all the biogenic amines were at a low level and the linear regression analysis revealed striking positive correlations of AUCTMA/AUCTotal with AUCPUT/AUCTotal (p\0.05) and AUCCAD/AUCTotal (p\0.001). The test shows 83% sensitivity and 92% specificity at a cut-off of AUCTMA/ AUCTotal=0.112 and AUC of receiver operator characteristic = 0.915 (0.81�0.97, 95% CI). Conclusions: VGTest-IMS is accurate and feasible for point-of-care testing of BV in the ambulatory care setting. Further evaluations are in progress to assess the utility of VGTest-IMS for differential diagnosis of candidosis, non-BV infection and common inflammatory conditions.

Biography :

Email: simon.lytton@t-online.de

Google Scholar citation report
Citations: 895

Metabolomics:Open Access received 895 citations as per Google Scholar report

Metabolomics:Open Access peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward