Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, Quebec, Canada
 Research Article   
								
																Plastic Hinge Length Requirements in Reinforced Concrete Couple Shear Wall Buildings for Seismic Reinforcement Detailing 
																Author(s): SK Amjad Hossain* and Bagchi Ashutosh             
								
																
						 Proper reinforcement detailing in plastic hinge regions is one of the important measures that could help damage control of structural walls subjected 
  to any severe earthquake event. Inelastic curvatures are commonly assumed to be uniform over a height called plastic hinge length. Non-linear 
  dynamic analyses are performed on a set of coupled shear wall buildings of simple configurations for different heights. Inelastic curvatures are 
  calculated on numerous heights of all the buildings and plotted along with the height of the buildings. Plastic hinge lengths are estimated with 
  the yield curvatures from analytical results. It becomes a common practice to estimate the plastic hinge length equal to 0.5 to 1.0 times the wall 
  length, which basically were developed from experimental studies on beam and column elements. As per the Canadian standards CSA A23.3-04, 
  the re.. Read More»
						  
																DOI:
								10.37421/2165-784X.2024.14.535															  
Journal of Civil and Environmental Engineering received 1798 citations as per Google Scholar report